Standards

EN 50288-7 Instrument Cables

BS 5308 Instrument Cables

PAS 5308 Instrument Cables

NF M87-202 Instrument Cables

ANSI/NEMA WC 53-2000/ANSI/NEMA WC 57-2004 Instrument Cables

Applications

Marine & Offshore Cables

Rolling Stock Cables

Fire Resistant Instrument Cables

Fire Retardant Instrument Cables

Special Application Cables

Pe Insulated, PVc sheathed & overall screened Instrumentation cables (Multicore)

re-2Y(st)Y 90°c / 500V

APPLICATION

For transmission of analogue and digital signals in instrument and control systems; allowed for use
in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for direct connection to low
impedance sources, e.g. public mains electricity supply.
Recommended for indoor and outerdoor installation, on racks, trays, in conduits, in dry and wet
locations; not for direct buiral.
Recommended for use as fire protection messure for people and important material assets.

STANDARDS

Basic design to EN50288-7

FIRE PERFORMANCE

Flame Retardance(SingleVerticalWireTest) EN60332-1-2;IEC60332-1-2;BSEN60332-1-2;VDE0482-332-1;NBNC30-004(cat.F1);NFC32-070-2.1(C2);CEI20-35/1-2;EN50265-2-1*;DINVDE0482-265-2-1*
Reduced Fire Propagation(Vertically-mountedbundledwires&cabletest) EN60332-3-24(cat.C);IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBNC30-004(cat.F2);NFC32-070-2.2(C1);CEI20-22/3-4;EN50266-2-4*;DINVDE0482-266-2-4
Halogen Free IEC60754-1;EN50267-2-1;DINVDE0482-267-2-1;CEI20-37/2-1;BS6425-1*
No Corrosive Gas Emission IEC60754-2;EN50267-2-2;DINVDE0482-267-2-2;CEI20-37/2-2;BS6425-2*
Minimum Smoke Emission IEC61034-1&2;EN61034-1&2;DINVDE0482-1034-1&2;CEI20-37/3-1&2;EN50268-1&2*;BS7622-1&2*
No Toxic gases NES02-713;NFC20-454
Sunlight Resistance UL1581section1200
Oil Resistance ICEAS-73-532**

Note:Asterisk*denotessupersededstandard,**denotesTesttemperature+60°C,duration4h.Retention:
min60%oftensilestrength/min.60%ofelongation,***denotesoptional.

VOLTAGERATING

500V

CABLE CONSTRUCTION

Conductor: Annealed copper solid or plain copper stranded to IEC 60228 Class 2.
Insulation: PE compound as per EN 50290. 2-23.
Overall Screen: Aluminium/polyester tape with 0.5mm2 screen (7/0.3mm) tinned copper drain wire.
Inner Sheath(optional): PVC compound
Armouring(optional): Galvanised steel wire
Outer Sheath: Thermoplastic PVC compound as per EN 50290-2-22. UV resistance, hydrocarbon
resistance, oil resistance, anti rodent and anti termite properties can be offered as option.
Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc)
depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also
be provided upon request.

COLOUR CODE

Insulation: Black / Blue, continuously numbered on blue core(1, 2..) for wrapped conductor
Outer Sheath: Black or blue for intrinsically safe systems

PHYSICALANDTHERMALPROPERTIES

Temperature Range During Operation (Fixed State): -30°C – +90°C
Temperature Range During Installation (Mobile State): -5°C – +50°C
Minimum Bending Radius: 7.5 X Overall Diameter
Sunlight Resistance: UL 1581 section 1200
Oil Resistance: ICEA S-73-532(Test temperature +60°C, duration 4h. Retention: min 60% of tensile
strength/min.60% of elongation)

ELECTRICALPROPERTIES

Conductor Area Size mm2 0.5 0.75 1.0 1.3 1.5 2.5
Insulation thickness (nominal) mm 0.55 0.55 0.55 0.6 0.6 0.7
Conductor resistance (20°C) Ω/km 36.0 24.5 18.1 13.9 12.1 7.4
Insulation resistance (20°C) MΩ.km(Min.) 5000
Mutual Capacitance (1 kHz) pF/m(Max.) 115
Capacitance unbalance(1 kHz) pF/500 m (Max.) 500
L / R (ratio) (max.) μH/Ω 25 25 25 40 40 60
Operating voltage V 500
Test Voltage Urms Core to Core V 2000
Core to Screen V 2000

CONSTRUCTIONPARAMETERS

Caledonian Cable Code RE-2Y(St)Y
No. of Cores x1xCross Section NominalInsulation Thickness NominalOuter Sheath Thickness NominalOverall Diameter Approx. Weight
  No.x1xmm2 mm mm mm kg/km
0.5mm2, Multicore
RE-2Y(St)Y 2C0.5 2x1x0.5 0.55 0.9 6.2 45
RE-2Y(St)Y 3C0.5 3x1x0.5 0.55 0.9 6.5 53
RE-2Y(St)Y 4C0.5 4x1x0.5 0.55 0.9 7.0 60
RE-2Y(St)Y 5C0.5 5x1x0.5 0.55 0.9 7.6 71
RE-2Y(St)Y 8C0.5 8x1x0.5 0.55 1.0 9.1 95
RE-2Y(St)Y 10C0.5 10x1x0.5 0.55 1.0 10.4 122
RE-2Y(St)Y 12C0.5 12x1x0.5 0.55 1.0 10.7 145
RE-2Y(St)Y 14C0.5 14x1x0.5 0.55 1.0 11.3 162
RE-2Y(St)Y 16C0.5 16x1x0.5 0.55 1.1 11.8 180
RE-2Y(St)Y 20C0.5 20x1x0.5 0.55 1.1 13.3 214
RE-2Y(St)Y 24C0.5 24x1x0.5 0.55 1.1 14.7 258
RE-2Y(St)Y 27C0.5 27x1x0.5 0.55 1.2 15.0 282
RE-2Y(St)Y 30C0.5 30x1x0.5 0.55 1.2 15.7 308
RE-2Y(St)Y 37C0.5 37x1x0.5 0.55 1.2 16.9 372
RE-2Y(St)Y 40C0.5 40x1x0.5 0.55 1.2 17.6 398
0.75mm2, Multicore
RE-2Y(St)Y 2C0.75 2x1x0.75 0.55 0.9 6.5   
RE-2Y(St)Y 3C0.75 3x1x0.75 0.55 0.9 6.9   
RE-2Y(St)Y 4C0.75 4x1x0.75 0.55 0.9 7.4   
RE-2Y(St)Y 5C0.75 5x1x0.75 0.55 0.9 8.1   
RE-2Y(St)Y 8C0.75 8x1x0.75 0.55 1.0 9.7   
RE-2Y(St)Y 10C0.75 10x1x0.75 0.55 1.0 11.1   
RE-2Y(St)Y 12C0.75 12x1x0.75 0.55 1.0 11.5   
RE-2Y(St)Y 14C0.75 14x1x0.75 0.55 1.1 12.2   
RE-2Y(St)Y 16C0.75 16x1x0.75 0.55 1.1 12.9   
RE-2Y(St)Y 20C0.75 20x1x0.75 0.55 1.1 14.3   
RE-2Y(St)Y 24C0.75 24x1x0.75 0.55 1.2 16.0   
RE-2Y(St)Y 27C0.75 27x1x0.75 0.55 1.2 16.3   
RE-2Y(St)Y 30C0.75 30x1x0.75 0.55 1.2 16.9   
RE-2Y(St)Y 37C0.75 37x1x0.75 0.55 1.2 18.2   
RE-2Y(St)Y 40C0.75 40x1x0.75 0.55 1.3 19.1   
1.0mm2, Multicore
RE-2Y(St)Y 2C1.0 2x1x1.0 0.55 0.9 6.9 58
RE-2Y(St)Y 3C1.0 3x1x1.0 0.55 0.9 7.3 70
RE-2Y(St)Y 4C1.0 4x1x1.0 0.55 0.9 7.9 85
RE-2Y(St)Y 5C1.0 5x1x1.0 0.55 0.9 8.6 98
RE-2Y(St)Y 8C1.0 8x1x1.0 0.55 1.0 10.3 136
RE-2Y(St)Y 10C1.0 10x1x1.0 0.55 1.0 11.9 194
RE-2Y(St)Y 12C1.0 12x1x1.0 0.55 1.0 12.2 214
RE-2Y(St)Y 14C1.0 14x1x1.0 0.55 1.1 13.0 243
RE-2Y(St)Y 16C1.0 16x1x1.0 0.55 1.1 13.7 280
RE-2Y(St)Y 20C1.0 20x1x1.0 0.55 1.1 15.2 336
RE-2Y(St)Y 24C1.0 24x1x1.0 0.55 1.2 17.0 404
RE-2Y(St)Y 27C1.0 27x1x1.0 0.55 1.2 17.4 443
RE-2Y(St)Y 30C1.0 30x1x1.0 0.55 1.2 18.0 484
RE-2Y(St)Y 37C1.0 37x1x1.0 0.55 1.2 19.6 590
RE-2Y(St)Y 40C1.0 40x1x1.0 0.55 1.3 20.4 632
1.3mm2, Multicore
RE-2Y(St)Y 2C1.3 2x1x1.3 0.6 0.9 7.4 72
RE-2Y(St)Y 3C1.3 3x1x1.3 0.6 0.9 7.9 86
RE-2Y(St)Y 4C1.3 4x1x1.3 0.6 0.9 8.5 105
RE-2Y(St)Y 5C1.3 5x1x1.3 0.6 1.0 9.5 135
RE-2Y(St)Y 8C1.3 8x1x1.3 0.6 1.0 11.2 176
RE-2Y(St)Y 10C1.3 10x1x1.3 0.6 1.1 13.2 228
RE-2Y(St)Y 12C1.3 12x1x1.3 0.6 1.1 13.6 269
RE-2Y(St)Y 14C1.3 14x1x1.3 0.6 1.1 14.3 305
RE-2Y(St)Y 16C1.3 16x1x1.3 0.6 1.1 15.0 351
RE-2Y(St)Y 20C1.3 20x1x1.3 0.6 1.2 16.9 423
RE-2Y(St)Y 24C1.3 24x1x1.3 0.6 1.2 18.7 507
RE-2Y(St)Y 27C1.3 27x1x1.3 0.6 1.3 19.3 558
RE-2Y(St)Y 30C1.3 30x1x1.3 0.6 1.3 20.0 611
RE-2Y(St)Y 37C1.3 37x1x1.3 0.6 1.3 21.6 743
RE-2Y(St)Y 40C1.3 40x1x1.3 0.6 1.4 22.7 796
1.5mm2, Multicore
RE-2Y(St)Y 2C1.5 2x1x1.5 0.6 0.9 7.7 78
RE-2Y(St)Y 3C1.5 3x1x1.5 0.6 0.9 8.1 94
RE-2Y(St)Y 4C1.5 4x1x1.5 0.6 0.9 8.8 116
RE-2Y(St)Y 5C1.5 5x1x1.5 0.6 1.0 9.8 149
RE-2Y(St)Y 8C1.5 8x1x1.5 0.6 1.0 11.6 196
RE-2Y(St)Y 10C1.5 10x1x1.5 0.6 1.1 13.7 261
RE-2Y(St)Y 12C1.5 12x1x1.5 0.6 1.1 14.1 300
RE-2Y(St)Y 14C1.5 14x1x1.5 0.6 1.1 14.8 340
RE-2Y(St)Y 16C1.5 16x1x1.5 0.6 1.1 15.6 392
RE-2Y(St)Y 20C1.5 20x1x1.5 0.6 1.2 17.6 474
RE-2Y(St)Y 24C1.5 24x1x1.5 0.6 1.3 19.6 567
RE-2Y(St)Y 27C1.5 27x1x1.5 0.6 1.3 20.1 625
RE-2Y(St)Y 30C1.5 30x1x1.5 0.6 1.3 20.8 685
RE-2Y(St)Y 37C1.5 37x1x1.5 0.6 1.4 22.6 834
RE-2Y(St)Y 40C1.5 40x1x1.5 0.6 1.4 23.6 898
2.52, Multicore
RE-2Y(St)Y 2C2.5 2x1x2.5 0.7 0.9 8.9 113
RE-2Y(St)Y 3C2.5 3x1x2.5 0.7 1.0 9.7 145
RE-2Y(St)Y 4C2.5 4x1x2.5 0.7 1.0 10.5 178
RE-2Y(St)Y 5C2.5 5x1x2.5 0.7 1.0 11.9 285
RE-2Y(St)Y 8C2.5 8x1x2.5 0.7 1.1 13.9 376
RE-2Y(St)Y 10C2.5 10x1x2.5 0.7 1.2 16.3 426
RE-2Y(St)Y 12C2.5 12x1x2.5 0.7 1.2 16.9 537
RE-2Y(St)Y 14C2.5 14x1x2.5 0.7 1.2 17.7 609
RE-2Y(St)Y 16C2.5 16x1x2.5 0.7 1.3 18.9 711
RE-2Y(St)Y 20C2.5 20x1x2.5 0.7 1.3 21.1 826
RE-2Y(St)Y 24C2.5 24x1x2.5 0.7 1.4 23.6 930
RE-2Y(St)Y 27C2.5 27x1x2.5 0.7 1.4 24.1 1040
RE-2Y(St)Y 30C2.5 30x1x2.5 0.7 1.5 25.2 1142
RE-2Y(St)Y 37C2.5 37x1x2.5 0.7 1.5 27.2 1392
RE-2Y(St)Y 40C2.5 40x1x2.5 0.7 1.6 28.5 1494

Note : Other conductor sizes & core configurations are available upon request.