Pe Insulated, PVc sheathed & overall screened Instrumentation cables (Multipair)

re-2Y(st)Y 90°c / 300V

EN 50288-7 Cables

APPLICATION

For transmission of analogue and digital signals in instrument and control systems; allowed for use
in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for direct connection to low
impedance sources, e.g. public mains electricity supply.
Recommended for indoor and outerdoor installation, on racks, trays, in conduits, in dry and wet
locations; not for direct buiral.
Recommended for use as fire protection messure for people and important material assets.

STANDARDS

Basicdesign to EN50288-7

FIREPERFORMANCE

FlameRetardance(SingleVerticalWireTest) EN60332-1-2;IEC60332-1-2;BSEN60332-1-2;VDE0482-332-1;NBNC30-004(cat.F1);NFC32-070-2.1(C2);CEI20-35/1-2;EN50265-2-1*;DINVDE0482-265-2-1*
ReducedFirePropagation(Vertically-mountedbundledwires&cabletest) EN60332-3-24(cat.C);IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBNC30-004(cat.F2);NFC32-070-2.2(C1);CEI20-22/3-4;EN50266-2-4*;DINVDE0482-266-2-4
HalogenFree IEC60754-1;EN50267-2-1;DINVDE0482-267-2-1;CEI20-37/2-1;BS6425-1*
NoCorrosiveGasEmission IEC60754-2;EN50267-2-2;DINVDE0482-267-2-2;CEI20-37/2-2;BS6425-2*
MinimumSmokeEmission IEC61034-1&2;EN61034-1&2;DINVDE0482-1034-1&2;CEI20-37/3-1&2;EN50268-1&2*;BS7622-1&2*
NoToxicgases NES02-713;NFC20-454

Note: Asterisk * denotes superseded standard, *** denotes optional.

VOLTAGERATING

300V

CABLECONSTRUCTION

Conductor: Annealed copper solid or plain copper stranded to IEC 60228 Class 2.
Insulation: PE compound as per EN 50290. 2-23.
Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm
Binder tape: PETP transparent tape
Overall Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in
contact with tinned copper drain wire, 0.5mm²
Outer Sheath: Thermoplastic PVC compound as per EN 50290-2-22. UV resistance, hydrocarbon
resistance, oil resistance, anti rodent and anti termite properties can be offered as option.
Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc)
depends on the oxygen index

COLOURCODE

Insulation: Black / White, continuously numbered on white core(1, 2..)for multipair.
Outer Sheath: Black or blue for intrinsically safe systems

PHYSICALANDTHERMALPROPERTIES

Temperature Range During Operation (Fixed State): -30°C – +90°C
Temperature Range During Installation (Mobile State): -5°C – +50°C
Minimum Bending Radius: 7.5 X Overall Diameter
Sunlight Resistance: UL 1581 section 1200
Oil Resistance: ICEA S-73-532(Test temperature +60°C, duration 4h. Retention: min 60% of tensile
strength/min.60% of elongation)

ELECTRICALPROPERTIES

Conductor Area Size mm 2 0.5 0.75 1.0 1.3 1.5
Insulation thickness (nominal) mm 0.35 0.38 0.4 0.45 0.45
Conductor resistance (20°C) Ω/km 36.7 25 18.5 14.2 12.3
Insulation resistance (20°C) MΩ.km(Min.) 5000
Mutual Capacitance (1 kHz) pF/m(Max.)   
   ≤ 4 pairs 90 90 90 102 102
     
   all other pairs 75 75 75 85 85
     
Capacitance unbalance(1 kHz) pF/500 m (Max.) 500
Inductance mH/km (Max.) 1
L / R (ratio) (max.) μH/Ω 25 25 25 40 40
Operating voltage Urms V 300

Test Voltage

Core to Core V 1500
Core to Screen V 1500

CONSTRUCTIONPARAMETERS

Caledonian Cable Code RE-2Y(St)Y
No. of Pairsx2 xCross Section Nominal Insulation Thickness Nominal Outer Sheath Thickness Nominal Overall Diameter

Approx. Weight

  No.x2xmm2 mm mm mm kg/km
0.5mm2, Multipair
RE-2Y(St)Y 2P0.5 2x2x0.5 0.35 0.9 7.6 66
RE-2Y(St)Y 4P0.5 4x2x0.5 0.35 0.9 8.8 98
RE-2Y(St)Y 5P0.5 5x2x0.5 0.35 1.0 9.8 118
RE-2Y(St)Y 6P0.5 6x2x0.5 0.35 1.0 10.6 138
RE-2Y(St)Y 8P0.5 8x2x0.5 0.35 1.0 11.3 160
RE-2Y(St)Y 10P0.5 10x2x0.5 0.35 1.1 12.9 201
RE-2Y(St)Y 12P0.5 12x2x0.5 0.35 1.1 13.5 236
RE-2Y(St)Y 16P0.5 16x2x0.5 0.35 1.1 15.2 300
RE-2Y(St)Y 20P0.5 20x2x0.5 0.35 1.2 16.9 367
RE-2Y(St)Y 24P0.5 24x2x0.5 0.35 1.2 18.3 419
0.75mm2, Multipair
RE-2Y(St)Y 2P0.75 2x2x0.75 0.38 0.9 8.5 87
RE-2Y(St)Y 4P0.75 3x2x0.75 0.38 1.0 10.0 123
RE-2Y(St)Y 5P0.75 4x2x0.75 0.38 1.0 10.9 150
RE-2Y(St)Y 6P0.75 5x2x0.75 0.38 1.0 11.8 175
RE-2Y(St)Y 8P0.75 8x2x0.75 0.38 1.1 12.8 220
RE-2Y(St)Y 10P0.75 10x2x0.75 0.38 1.1 14.5 267
RE-2Y(St)Y 12P0.75 12x2x0.75 0.38 1.1 15.1 298
RE-2Y(St)Y 16P0.75 16x2x0.75 0.38 1.2 17.3 409
RE-2Y(St)Y 20P0.75 20x2x0.75 0.38 1.3 19.2 480
RE-2Y(St)Y 24P0.75 24x2x0.75 0.38 1.3 20.8 561
1.0mm2, Multipair
RE-2Y(St)Y 2P1.0 2x2x1.0 0.4 0.9 9.2 102
RE-2Y(St)Y 4P1.0 3x2x1.0 0.4 1.0 10.9 156
RE-2Y(St)Y 5P1.0 4x2x1.0 0.4 1.0 11.9 183
RE-2Y(St)Y 6P1.0 5x2x1.0 0.4 1.0 13.0 224
RE-2Y(St)Y 8P1.0 8x2x1.0 0.4 1.1 14.0 273
RE-2Y(St)Y 10P1.0 10x2x1.0 0.4 1.1 15.9 324
RE-2Y(St)Y 12P1.0 12x2x1.0 0.4 1.2 16.8 383
RE-2Y(St)Y 16P1.0 16x2x1.0 0.4 1.2 19.0 513
RE-2Y(St)Y 20P1.0 20x2x1.0 0.4 1.3 21.1 619
RE-2Y(St)Y 24P1.0 24x2x1.0 0.4 1.4 23.1 738
1.3mm2, Multipair
RE-2Y(St)Y 2P1.3 2x2x1.3 0.45 1.0 10.4 122
RE-2Y(St)Y 4P1.3 3x2x1.3 0.45 1.0 12.0 190
RE-2Y(St)Y 5P1.3 4x2x1.3 0.45 1.1 13.4 233
RE-2Y(St)Y 6P1.3 5x2x1.3 0.45 1.1 14.6 273
RE-2Y(St)Y 8P1.3 8x2x1.3 0.45 1.2 15.7 330
RE-2Y(St)Y 10P1.3 10x2x1.3 0.45 1.2 17.9 422
RE-2Y(St)Y 12P1.3 12x2x1.3 0.45 1.3 18.9 487
RE-2Y(St)Y 16P1.3 16x2x1.3 0.45 1.3 21.4 678
RE-2Y(St)Y 20P1.3 20x2x1.3 0.45 1.4 23.8 790
RE-2Y(St)Y 24P1.3 24x2x1.3 0.45 1.5 25.9 921
1.5mm2, Multipair
RE-2Y(St)Y 2P1.5 2x2x1.5 0.45 1.0 10.8 139
RE-2Y(St)Y 4P1.5 3x2x1.5 0.45 1.1 12.7 212
RE-2Y(St)Y 5P1.5 4x2x1.5 0.45 1.1 14.0 259
RE-2Y(St)Y 6P1.5 5x2x1.5 0.45 1.2 15.2 312
RE-2Y(St)Y 8P1.5 8x2x1.5 0.45 1.2 16.4 378
RE-2Y(St)Y 10P1.5 10x2x1.5 0.45 1.3 18.8 473
RE-2Y(St)Y 12P1.5 12x2x1.5 0.45 1.3 19.7 548
RE-2Y(St)Y 16P1.5 16x2x1.5 0.45 1.4 22.5 727
RE-2Y(St)Y 20P1.5 20x2x1.5 0.45 1.5 25.0 903
RE-2Y(St)Y 24P1.5 24x2x1.5 0.45 1.5 27.1 1051

Note : Other conductor sizes & core configurations are available upon request.