EN 50288-7 Satandard XLPE Insulated, LSZH Sheathed & Overall Screened Instrumentation Cables (Multitriple)

RE-2X(St)H 90??C / 300V

EN 50288-7 multitriple cables

Application

EN 50288-7 multitriple cables for transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for direct connection to low impedance sources, e.g. public mains electricity supply.
Recommended for indoor and outerdoor installation, on racks, trays, in conduits, in dry and wet locations; not for direct buiral.
Recommended for use as fire protection messure for people and important material assets.

Flame Performance

Flame Retardance (Single Vertical Wire Test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
Halogen Free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
Minimum Smoke Emission IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gases NES 02-713; NF C 20-454

Construction

Conductor Annealed bare copper, stranded to IEC 60228 Class 2.
Insulation Extruded cross-linked XLPE compound as per EN 50290-2-29.
Triple Three conductors twisted to form a triple.
Collective screen Aluminium/polyester tape with tinned copper drain wire, 0.5mm2
Outer sheath LSZH compound as per EN 50290-2-27. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.

Colour Code

Insulation: Black / White / Red, continuously numbered on white core(1, 2..)for multitriples.
Outer Sheath: Black or blue for intrinsically safe systems

Mechanical

Temperature Range During Operation (Fixed State) -30??C ?C +90??C
Temperature Range During Installation (Mobile State) -5??C ?C +50??C
Minimum Bending Radius 7.5 X Overall Diameter
Sunlight Resistance UL 1581 section 1200
Oil Resistance ICEA S-73-532(Test temperature +60??C
duration 4h. Retention: min 60% of tensile
strength/min.60% of elongation)

Electrical Properties

Conductor Area Size? mm 2? 0.5 0.75 1 1.3 1.5
Insulation thickness (nominal)? mm? 0.55 0.55 0.55 0.6 0.6
Conductor resistance (20??C)? ??/km? 36.7 25 18.5 14.2 12.3
Insulation resistance (20??C)? M??.km(Min.)? 5000
Mutual Capacitance (1 kHz)? pF/m(Max.)? 115
Capacitance unbalance(1 kHz)? pF/500 m (Max.)? 500
L / R (ratio) (max.)? ??H/??? 25 25 25 40 40 60
Operating voltage? V? 500
Test Voltage Urms? Core to Core V? 2000
Core to Screen? V? 2000

Construction Parameters

Caledonian Cable Code RE-2X(St)H
?No. of Core x1xCross Section Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Approx. Weight
No.x1xmm2 mm mm mm kg/km
0.5mm2 , Multi-striple?
RE-2X(St)H 2T0.5 2x3x0,50 0.35 0.9 8.4 91
RE-2X(St)H 4T0.5 4x3x0,50 0.35 1 9.8 123
RE-2X(St)H 5T0.5 5x3x0,50 0.35 1 10.8 155
RE-2X(St)H 6T0.5 6x3x0,50 0.35 1 12.1 185
RE-2X(St)H 8T0.5 8x3x0,50 0.35 1.1 13.1 221
RE-2X(St)H 10T0.5 10x3x0,50 0.35 1.1 14.7 275
RE-2X(St)H 12T0.5 12x3x0,50 0.35 1.1 15.2 316
RE-2X(St)H 16T0.5 16x3x0,50 0.35 1.2 17.4 414
RE-2X(St)H 20T0.5 20x3x0,50 0.35 1.2 19.1 508
RE-2X(St)H 24T0.5 24x3x0,50 0.35 1.3 20.9 594
0.75mm2, Multi-striple?
RE-2X(St)H 2T0.75 2x3x0,75 0.38 0.9 9.3 114
RE-2X(St)H 4T0.75 4x3x0,75 0.38 1 10.9 163
RE-2X(St)H 5T0.75 5x3x0,75 0.38 1 12 199
RE-2X(St)H 6T0.75 6x3x0,75 0.38 1.1 13.7 245
RE-2X(St)H 8T0.75 8x3x0,75 0.38 1.1 14.7 296
RE-2X(St)H 10T0.75 10x3x0,75 0.38 1.2 16.7 366
RE-2X(St)H 12T0.75 12x3x0,75 0.38 1.2 17.3 423
RE-2X(St)H 16T0.75 16x3x0,75 0.38 1.3 19.7 555
RE-2X(St)H 20T0.75 20x3x0,75 0.38 1.3 21.7 681
RE-2X(St)H 24T0.75 24x3x0,75 0.38 1.4 23.7 802
1.0mm2 , Multi-striple?
RE-2X(St)H 2T1.0 2x3x1 0.4 1 10.4 135
RE-2X(St)H 4T1.0 4x3x1 0.4 1 11.9 202
RE-2X(St)H 5T1.0 5x3x1 0.4 1 13.2 251
RE-2X(St)H 6T1.0 6x3x1 0.4 1.1 15 303
RE-2X(St)H 8T1.0 8x3x1 0.4 1.1 16.1 379
RE-2X(St)H 10T1.0 10x3x1 0.4 1.2 18.4 461
RE-2X(St)H 12T1.0 12x3x1 0.4 1.2 19 544
RE-2X(St)H 16T1.0 16x3x1 0.4 1.3 21.7 717
RE-2X(St)H 20T1.0 20x3x1 0.4 1.4 24.1 880
RE-2X(St)H 24T1.0 24x3x1 0.4 1.4 26.1 1048
1.3mm2 , Multi-striple?
RE-2X(St)H 2T1.3 2x3x1,3 0.45 1 11.5 175
RE-2X(St)H 4T1.3 4x3x1,3 0.45 1.1 13.4 258
RE-2X(St)H 5T1.3 5x3x1,3 0.45 1.1 14.8 318
RE-2X(St)H 6T1.3 6x3x1,3 0.45 1.2 16.9 387
RE-2X(St)H 8T1.3 8x3x1,3 0.45 1.2 18.1 474
RE-2X(St)H 10T1.3 10x3x1,3 0.45 1.3 20.7 589
RE-2X(St)H 12T1.3 12x3x1,3 0.45 1.3 21.4 695
RE-2X(St)H 16T1.3 16x3x1,3 0.45 1.4 24.4 918
RE-2X(St)H 20T1.3 20x3x1,3 0.45 1.5 27.1 1124
RE-2X(St)H 24T1.3 24x3x1,3 0.45 1.6 29.6 1336
1.5mm2 , Multi-striple?
RE-2X(St)H 2T1.5 2x3x1,5 0.45 1 11.9 191
RE-2X(St)H 4T1.5 4x3x1,5 0.45 1.1 14 287
RE-2X(St)H 5T1.5 5x3x1,5 0.45 1.1 15.4 355
RE-2X(St)H 6T1.5 6x3x1,5 0.45 1.2 17.6 432
RE-2X(St)H 8T1.5 8x3x1,5 0.45 1.3 19.1 540
RE-2X(St)H 10T1.5 10x3x1,5 0.45 1.3 21.6 672
RE-2X(St)H 12T1.5 12x3x1,5 0.45 1.4 22.5 779
RE-2X(St)H 16T1.5 16x3x1,5 0.45 1.5 25.7 1031
RE-2X(St)H 20T1.5 20x3x1,5 0.45 1.6 28.6 1265
RE-2X(St)H 24T1.5 24x3x1,5 0.45 1.7 31.1 1508