Standards

EN 50288-7 Instrument Cables

BS 5308 Instrument Cables

PAS 5308 Instrument Cables

NF M87-202 Instrument Cables

ANSI/NEMA WC 53-2000/ANSI/NEMA WC 57-2004 Instrument Cables

Applications

Marine & Offshore Cables

Rolling Stock Cables

Fire Resistant Instrument Cables

Fire Retardant Instrument Cables

Special Application Cables

  • Home
  • Product
  • EN 50288-7

XLPE Insulated, PVC Sheathed & Overall Screened

RE-2X(St)H 90°C/300V

EN 50288-7 Cables

APPLICATION:

For transmission of analogue and digital signals in instrument and control systems; allowed for use  in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for direct connection to low  impedance sources, e.g. public mains electricity supply. Recommended for indoor and outerdoor installation, on racks, trays, in conduits, in dry and wet  locations; not for direct buiral.
Recommended for use as fire protection messure for people and important material assets.

STANDARDS

BasicdesigntoEN50288-7

FIREPERFORMANCE

Flame Retardance (Single Vertical WireTest)

EN60332-1-2;IEC60332-1-2;BSEN60332-1-2;VDE0482-332-1;NBNC30-004(cat.F1);NFC32-070-2.1(C2);CEI20-35/1-2;EN50265-2-1*;DINVDE0482-265-2-1*

Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)

EN60332-3-24(cat.C);IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBNC30-004(cat.F2);NFC32-070-2.2(C1);CEI20-22/3-4;EN50266-2-4*;DINVDE0482-266-2-4

Halogen Free

IEC60754-1;EN50267-2-1;DINVDE0482-267-2-1;CEI20-37/2-1;BS6425-1*

No Corrosive Gas Emission

IEC60754-2;EN50267-2-2;DINVDE0482-267-2-2;CEI20-37/2-2;BS6425-2*

Minimum Smoke Emission

IEC61034-1&2;EN61034-1&2;DINVDE0482-1034-1&2;CEI20-37/3-1&2;EN50268-1&2*;BS7622-1&2*

No Toxic gases

NES02-713;NFC20-454

SunlightResistance

UL1581section1200

OilResistance

ICEAS-73-532**

Note:Asterisk*denotes superseded standard,**de notesTest temperature+60°C,duration 4h.Re tention
:min 60% of tensile strength/min.60%of elongation,***de note soptional.

VOLTAGE RATING

300V

CABLE CONSTRUCTION

Conductor: Annealed bare copper, stranded to IEC 60228 Class 2.
Insulation: Extruded cross-linked XLPE compound as per EN 50290-2-29.
Triple: Three conductors twisted to form a triple
Lay-up: Triples laid up in layers of optimum pitch
Separator: Polyester tape
Overall Screen: Aluminium/polyester tape with tinned copper drain wire, 0.5mm2
Outer Sheath: LSZH compound as per EN 50290-2-27. UV resistance, hydrocarbon resistance, oil
resistance, anti rodent and anti termite properties can be offered as option.

COLOUR CODE

Insulation: Black / White, continuously numbered on white core(1, 2..)for multipair.
Outer Sheath: Black or blue for intrinsically safe systems

PHYSICAL AND THERMALPROPERTIES

TemperatureRangeDuringOperation(FixedState):-30°C–+90°C
TemperatureRangeDuringInstallation(MobileState):-5°C–+50°C
MinimumBendingRadius:7.5XOverallDiameter

ELECTRICAL PROPERTIES

ConductorAreaSize 2 0.5 0.75 1.0 1.3 1.5
Insulationthickness(nominal) mm 0.35 0.38 0.4 0.45 0.45
Conductorresistance(20°C) Ω/km 36.7 25.0 18.5 14.2 12.3
Insulationresistance(20°C) MΩ.km(Min.) 5000
MutualCapacitance(1kHz) upto4trplespF/m(Max.) 90 90 90 102 102
    above4trplespF/m(Max.) 75 75 75 85 85
Inductance mH/km(Max.) 1
L/R(ratio)(max.) μH/Ω 25 25 25 40 40
Operatingvoltage V 300
TestVoltageUrms CoretoCore V 1500
CoretoScreen V 1500

CONSTRUCTION PARAMETERS

Caledonian Cable Code RE-2X(St)Y
No. of Triples x3xCross Section Nominal Insulation Thickness Nominal Outer Sheath Thickness Nominal Overall Diameter

Approx. Weight

  No.x3xmm2 mm mm mm kg/km
0.5mm2 , Multi-striple
RE-2X(St)Y 2T0.5 2x3x0,50 0.35 0.9 8.4 91
RE-2X(St)Y 4T0.5 4x3x0,50 0.35 1.0 9.8 123
RE-2X(St)Y 5T0.5 5x3x0,50 0.35 1.0 10.8 155
RE-2X(St)Y 6T0.5 6x3x0,50 0.35 1.0 12.1 185
RE-2X(St)Y 8T0.5 8x3x0,50 0.35 1.1 13.1 221
RE-2X(St)Y 10T0.5 10x3x0,50 0.35 1.1 14.7 275
RE-2X(St)Y 12T0.5 12x3x0,50 0.35 1.1 15.2 316
RE-2X(St)Y 16T0.5 16x3x0,50 0.35 1.2 17.4 414
RE-2X(St)Y 20T0.5 20x3x0,50 0.35 1.2 19.1 508
RE-2X(St)Y 24T0.5 24x3x0,50 0.35 1.3 20.9 594
0.75mm2 , Multi-striple
RE-2X(St)Y 2T0.75 2x3x0,75 0.38 0.9 9.3 114
RE-2X(St)Y 4T0.75 4x3x0,75 0.38 1.0 10.9 163
RE-2X(St)Y 5T0.75 5x3x0,75 0.38 1.0 12.0 199
RE-2X(St)Y 6T0.75 6x3x0,75 0.38 1.1 13.7 245
RE-2X(St)Y 8T0.75 8x3x0,75 0.38 1.1 14.7 296
RE-2X(St)Y 10T0.75 10x3x0,75 0.38 1.2 16.7 366
RE-2X(St)Y 12T0.75 12x3x0,75 0.38 1.2 17.3 423
RE-2X(St)Y 16T0.75 16x3x0,75 0.38 1.3 19.7 555
RE-2X(St)Y 20T0.75 20x3x0,75 0.38 1.3 21.7 681
RE-2X(St)Y 24T0.75 24x3x0,75 0.38 1.4 23.7 802
1.0mm2 , Multi-striple
RE-2X(St)Y 2T1.0 2x3x1 0.4 1.0 10.4 135
RE-2X(St)Y 4T1.0 4x3x1 0.4 1.0 11.9 202
RE-2X(St)Y 5T1.0 5x3x1 0.4 1.0 13.2 251
RE-2X(St)Y 6T1.0 6x3x1 0.4 1.1 15.0 303
RE-2X(St)Y 8T1.0 8x3x1 0.4 1.1 16.1 379
RE-2X(St)Y 10T1.0 10x3x1 0.4 1.2 18.4 461
RE-2X(St)Y 12T1.0 12x3x1 0.4 1.2 19.0 544
RE-2X(St)Y 16T1.0 16x3x1 0.4 1.3 21.7 717
RE-2X(St)Y 20T1.0 20x3x1 0.4 1.4 24.1 880
RE-2X(St)Y 24T1.0 24x3x1 0.4 1.4 26.1 1048
1.3mm2 , Multi-striple
RE-2X(St)Y 2T1.3 2x3x1,3 0.45 1.0 11.5 175
RE-2X(St)Y 4T1.3 4x3x1,3 0.45 1.1 13.4 258
RE-2X(St)Y 5T1.3 5x3x1,3 0.45 1.1 14.8 318
RE-2X(St)Y 6T1.3 6x3x1,3 0.45 1.2 16.9 387
RE-2X(St)Y 8T1.3 8x3x1,3 0.45 1.2 18.1 474
RE-2X(St)Y 10T1.3 10x3x1,3 0.45 1.3 20.7 589
RE-2X(St)Y 12T1.3 12x3x1,3 0.45 1.3 21.4 695
RE-2X(St)Y 16T1.3 16x3x1,3 0.45 1.4 24.4 918
RE-2X(St)Y 20T1.3 20x3x1,3 0.45 1.5 27.1 1124
RE-2X(St)Y 24T1.3 24x3x1,3 0.45 1.6 29.6 1336
1.5mm2 , Multi-striple
RE-2X(St)Y 2T1.5 2x3x1,5 0.45 1.0 11.9 191
RE-2X(St)Y 4T1.5 4x3x1,5 0.45 1.1 14.0 287
RE-2X(St)Y 5T1.5 5x3x1,5 0.45 1.1 15.4 355
RE-2X(St)Y 6T1.5 6x3x1,5 0.45 1.2 17.6 432
RE-2X(St)Y 8T1.5 8x3x1,5 0.45 1.3 19.1 540
RE-2X(St)Y 10T1.5 10x3x1,5 0.45 1.3 21.6 672
RE-2X(St)Y 12T1.5 12x3x1,5 0.45 1.4 22.5 779
RE-2X(St)Y 16T1.5 16x3x1,5 0.45 1.5 25.7 1031
RE-2X(St)Y 20T1.5 20x3x1,5 0.45 1.6 28.6 1265
RE-2X(St)Y 24T1.5 24x3x1,5 0.45 1.7 31.1 1508