Standards

EN 50288-7 Instrument Cables

BS 5308 Instrument Cables

PAS 5308 Instrument Cables

NF M87-202 Instrument Cables

ANSI/NEMA WC 53-2000/ANSI/NEMA WC 57-2004 Instrument Cables

Applications

Marine & Offshore Cables

Rolling Stock Cables

Fire Resistant Instrument Cables

Fire Retardant Instrument Cables

Special Application Cables

FIREROL Thin Wall Multi-Core Overall Screened Cables with Exposed Standard Wall Sheath 300/500V

EN 50306-4 (FRL-TW-05M-ESW-OS)

Application :

-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.

-Used in cable harnesses, switchboards and control panels, driver desks etc.

Construction :

Conductor Tinned annealed copper wires as defined in EN 50306-2
Insulation LSZH special compound
Overal screen Tinned annealed copper wires
Outer sheath LSZH special compound as defined in EN 50264-1 (S2. EM 101 - EM 104)

A. Conductor

B. Insulation

C. Screen

D. Sheath

Electrical & Mechanical Properties :

Nominal Voltage 300/500 V
Maximum Conductor Temperature 90°C /105°C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40°C (fixed installation)
Bending Radius 10 x Overall Diameter

Chemical & Environmental Properties :

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone

Fire Performance for rolling stock application :

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 F0
EN45545-2 R15 Interior/ R16 Exterior HL1, HL2, HL3

Fire Performance in General :

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101 Smoke index
EN45545-2 Requirement for fire behavior of materials & components R15/R 16

FRL-TW-05M-ESW-OS 300/500 V :

Number of Cores and
Nominal Cross Section
Minimum Thickness of
Sheath at any Point
Overall Diameter Weight
min. max.
n x mm2 mm mm mm kg/km
2 x 0.5 1.0 5.5 6.5 50
3 x 0.5 1.0 5.7 6.7 55
4 x 0.5 1.0 6.1 7.1 60
6 x 0.5 1.0 6.9 7.9 90
8 x 0.5 1.0 7.5 8.5 110
 
2 x 0.75 1.0 5.9 6.9 60
3 x 0.75 1.0 6.2 7.2 70
4 x 0.75 1.0 6.5 7.5 80
6 x 0.75 1.0 7.5 8.5 110
8 x 0.75 1.0 8.2 9.2 130
 
2 x 1.0 1.0 6.2 7.2 60
3 x 1.0 1.0 6.5 7.5 80
4 x 1.0 1.0 6.9 7.9 90
6 x 1.0 1.0 8.0 9.0 130
8 x 1.0 1.0 8.6 9.8 160
 
2 x 1.5 1.0 7.1 8.1 90
3 x 1.5 1.0 7.4 8.4 110
4 x 1.5 1.0 8.0 9.0 130
6 x 1.5 1.0 9.2 10.4 170
8 x 1.5 1.0 10.2 11.4 220
 
2 x 2.5 1.0 8.3 9.3 120
3 x 2.5 1.0 8.6 9.8 150
4 x 2.5 1.0 9.4 10.6 180
Corona Resistant Cables Highly Flexible Cables UV Resistant Cables Ozone Resistant Cables Abrasion Retardant Cables Cold resistant Cables<
Corona Resistant Highly Flexible UV Resistant Ozone Resistant Abrasion Retardant Cold- resistant
Resistance To Soldering Heat Cables Acid&Alkaline Resistant Cables IRM 903 Fuel Oil Resistant Cables IRM 902
Mineral Oil Resistant Cables Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4 cables Flame Retardant NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1 cables
Resistance To Soldering Heat Acid&Alkaline Resistant IRM 903 Fuel Oil Resistant IRM 902
Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853 cables Low Corrosivity
IEC60754-2/EN50267-2-2/3 NF C32-074/VDE 0472-813 Cables Low Smoke Emission
IEC 61034-2 / EN 50268-2 NF C32-073/VDE 0472-816 cables Zero Halogen
IEC 60754-1/EN 50267-2-1
NF C32-074//VDE 0472-815 cables    
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
IEC60754-2/EN50267-2-2/3 NF C32-074/VDE 0472-813
Low Smoke Emission
IEC 61034-2 / EN 50268-2 NF C32-073/VDE 0472-816
Zero Halogen